Description
PLEASE ALLOW ADDITIONAL TIME FOR SHIPMENT OF THIS PRODUCT.CONTACT USVIA PHONE OREMAILTO REQUEST MORE INFORMATION ON AVAILABILITY.
The Dresser D800 and D1000 meters carry a legacy of excellent, long-term rotary meter performance in a lightweight, compact, oil-free design. The D800 and D1000 meters cover a range of meter sizes (600-1700cfh),
Dresser D800 and D1000 meters average start rate of only 0.30 ACFH (stop rate of 0.15 ACFH) and a rapid ramp up to +/- 1% accuracy at only 8 ACFH, the D800 and D1000 provide a sustained, continuous, nonadjustable measurement accuracy from pilot loads up to 1700 ACFH.
* Preferred replacement for meters such as the AL-800 (AL800), AL-1000 (AL1000), AC-800, Sonix 880 and Sonix IQ Ultrasonic Gas Meter.
Temperature Measurement System
Extremely Stable Class A, PT1000 precision RTD
Range: -40 to 140F (-40 to 60C)
Total ambient temperature effect: Less than 0.1F (0.05C) over entire temperature range
Temperature Reading Accuracy
-40F to 140F: +/- 0.9F (-40C to 60C: +/- 0.5C)
Environmental Conditions
Ambient temperature range: -40 to 140F (-40 to 60C)
Ambient humidity range: 0 to 100 non-condensing
Ferrule (Spud) Connections
30LT/45LT/#3, #4 Sprague/#5 Sprague/1-1/2 FNPT
Spud to Spud: 11 inches (279.4 mm)
Maximum Operating Pressure (MAOP)
25 psig
Certifications
CSA: Class 1, Div 1, Group A, B, C and D Certification
Meets internationally recognized standards for moisture ingress protection (IP 65 and IP 66)
Electromagnetic Compliance per IEC standards
Electrostatic Discharge compliance per IEC standards
Measurement Canada Approved (AG-0611)
Standards
Dresser D800/D1000 meters are manufactured in accordance with ANSI B109.3 for Rotary Type Gas Displacement Meters
Resources:
- D800/D1000 Brochure
- D1000 Data Sheet